Cart Empty
Tripp SMART2500XLHG , Smartpro Medical Grade Ups, Tower, 2.2kva, Snmp, Usb, Db9, 4 5-1520r, 4 C13
Make an offer
Technical InformationPlug/Connector Type: IEC 60320 C20Receptacles: 4 x IEC 60320 C13, 4 x NEMA 5-15/20RTransfer Time: 4 msPower DescriptionLoad Capacity: 2200 VA/1920 WInput Voltage: 120 V ACOutput Voltage: 120 V ACInterfaces/PortsSerial Port: YesUSB: YesBattery InformationBackup/Run Time (Full Load): 4.40 MinuteBackup/Run Time (Half Load): 13 MinuteTypical Battery Recharge Time: 4.50 HourHot Swappable: YesPhysical CharacteristicsHeight: 9.3"Width: 8.9"Depth: 19.1"Form Factor: TowerWeight (Approximate): 73.30 lbMiscellaneousPackage Contents: SMART 2500XLHG Medical Grade Tower UPS SystemPoweralert Software CDWarranty InformationInstruction ManualUSB CableDB9 CableCertifications & Standards: UL1778CSAFCC Part 15UL60601-1Software Included: PowerAlert SoftwareEnvironmentally Friendly: YesEnvironmental Certification: RoHSWarrantyLimited Warranty: 2 Year
OUTPUT
Output Volt Amp Capacity (VA):2200
Output kVA capacity (kVA):2.2
Output Watt Capacity (watts):1920
Output power factor:0.87
Nominal Output Voltage(s) Supported:115V 120V
Frequency compatibility:60 Hz Output voltage regulation (line mode):-18%, +8%
Output voltage regulation (Battery mode):115V (+/- 5%)
Built-in UPS output receptacles:4 5-15/20R outlet(s) 4 C13 outlet(s)
Output receptacle details:Hospital grade output receptacles
Output AC waveform (AC mode):Sine wave
Output AC waveform (battery mode):PWM sine wave INPUT
Rated input current (at maximum load):9.2A
Nominal Input Voltage(s) Supported:120V AC
UPS input connection type:C20 inlet
Input circuit breaker:15A
UPS Input cord length (ft.):6
UPS Input cord length (m):1.8
Recommended Electrical Service:15A 120V BATTERY
Full load runtime (minutes):4.4 minutes
Half load runtime (minutes):13 minutes
Expandable battery runtime:Extended runtime supported via optional external battery packs
External battery pack compatibility:BP48V24-2U (limit 1) BP48V60RT-3U (multi-pack compatible) DC system voltage (VDC):48
Battery recharge rate (included batteries):4.5 hours MAX (10% to 90% capacity) Internal batteries only
Replacement battery cartridge (internal UPS battery replacement):RBC48V-HGTWR
Battery Access:Battery access door
Battery replacement description:Hot-swappable, user replaceable batteries VOLTAGE REGULATION
Voltage regulation description:Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143
Overvoltage correction:Input voltages between 126 and 143 are reduced by 9% Undervoltage correction:Input voltages between 96 and 106 are boosted by 10%
Severe undervoltage correction:Input voltages between 81 and 95 are boosted by 21% LEDS ALARMS and SWITCHES
LED Indicators:5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Alarms:Audible alarm indicates power-failure, overload and low-battery conditions Alarm cancel operation:Power-fail alarm can be silenced using alarm-cancel switch once silenced, alarm will re-sound to indicate low-battery status
Switches:2 Switches control off/on power status and alarm-cancel/self-test operation SURGE / NOISE SUPPRESSION
UPS AC suppression joule rating:510
UPS AC suppression response time:Instantaneous
EMI / RFI AC noise suppression:Yes ISOLATION
Output isolation transformer:Hospital grade load isolation transformer
Leakage current:Equal to 100 microamps
Installation form factors supported with included accessories:
Tower Installation form factors supported with optional accessories:
Wallmount (UPSWM - tower mounting kit)
Primary form factor:
Tower
UPS housing material:
PVC
Cooling method:
Fan LINE / BATTERY TRANSFER
Transfer time:2-4 milliseconds
Low voltage transfer to battery power (setpoint):81
High voltage transfer to battery power (setpoint):143 SPECIAL FEATURES
Cold Start (startup in battery mode during a power failure):Cold-start operation supported
High availability UPS features:Hot swappable batteries CERTIFICATIONS
UPS Certifications:Tested to UL1778 (USA) Tested to CSA (Canada) Meets FCC Part 15 Category A (EMI) Tested to UL60601-1 (medical grade) Item Dimension (L"xW"xH"):
15.94 x 14.17 x 23.43
Weight:
95.4 lb
Warranty Information:
2-year limited warranty
Output Volt Amp Capacity (VA):2200
Output kVA capacity (kVA):2.2
Output Watt Capacity (watts):1920
Output power factor:0.87
Nominal Output Voltage(s) Supported:115V 120V
Frequency compatibility:60 Hz Output voltage regulation (line mode):-18%, +8%
Output voltage regulation (Battery mode):115V (+/- 5%)
Built-in UPS output receptacles:4 5-15/20R outlet(s) 4 C13 outlet(s)
Output receptacle details:Hospital grade output receptacles
Output AC waveform (AC mode):Sine wave
Output AC waveform (battery mode):PWM sine wave INPUT
Rated input current (at maximum load):9.2A
Nominal Input Voltage(s) Supported:120V AC
UPS input connection type:C20 inlet
Input circuit breaker:15A
UPS Input cord length (ft.):6
UPS Input cord length (m):1.8
Recommended Electrical Service:15A 120V BATTERY
Full load runtime (minutes):4.4 minutes
Half load runtime (minutes):13 minutes
Expandable battery runtime:Extended runtime supported via optional external battery packs
External battery pack compatibility:BP48V24-2U (limit 1) BP48V60RT-3U (multi-pack compatible) DC system voltage (VDC):48
Battery recharge rate (included batteries):4.5 hours MAX (10% to 90% capacity) Internal batteries only
Replacement battery cartridge (internal UPS battery replacement):RBC48V-HGTWR
Battery Access:Battery access door
Battery replacement description:Hot-swappable, user replaceable batteries VOLTAGE REGULATION
Voltage regulation description:Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143
Overvoltage correction:Input voltages between 126 and 143 are reduced by 9% Undervoltage correction:Input voltages between 96 and 106 are boosted by 10%
Severe undervoltage correction:Input voltages between 81 and 95 are boosted by 21% LEDS ALARMS and SWITCHES
LED Indicators:5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Alarms:Audible alarm indicates power-failure, overload and low-battery conditions Alarm cancel operation:Power-fail alarm can be silenced using alarm-cancel switch once silenced, alarm will re-sound to indicate low-battery status
Switches:2 Switches control off/on power status and alarm-cancel/self-test operation SURGE / NOISE SUPPRESSION
UPS AC suppression joule rating:510
UPS AC suppression response time:Instantaneous
EMI / RFI AC noise suppression:Yes ISOLATION
Output isolation transformer:Hospital grade load isolation transformer
Leakage current:Equal to 100 microamps
Installation form factors supported with included accessories:
Tower Installation form factors supported with optional accessories:
Wallmount (UPSWM - tower mounting kit)
Primary form factor:
Tower
UPS housing material:
PVC
Cooling method:
Fan LINE / BATTERY TRANSFER
Transfer time:2-4 milliseconds
Low voltage transfer to battery power (setpoint):81
High voltage transfer to battery power (setpoint):143 SPECIAL FEATURES
Cold Start (startup in battery mode during a power failure):Cold-start operation supported
High availability UPS features:Hot swappable batteries CERTIFICATIONS
UPS Certifications:Tested to UL1778 (USA) Tested to CSA (Canada) Meets FCC Part 15 Category A (EMI) Tested to UL60601-1 (medical grade) Item Dimension (L"xW"xH"):
15.94 x 14.17 x 23.43
Weight:
95.4 lb
Warranty Information:
2-year limited warranty
- Manufacturer:
- Model Number:
- Condition:
- Weight:
- Dimensions:
- Updated:
- Added:
- Tripp Lite
- SMART2500XLHG
- New
- 95.40lbs
- 23 X 16 X 14
- Dec 04, 2024
- Feb 29, 2020
Request For Quote.
Tripp SMART2500XLHG , Smartpro Medical Grade Ups, Tower, 2.2kva, Snmp, Usb, Db9, 4 5-1520r, 4 C13