Cart Empty
Tripp PDU3VN6L1530B Tripp-lite Pdu 10kw 3-phase Metered 200208240v 42xc136xc19 Retail
Make an offer
Tripp PDU3VN6L1530B Tripp-lite Pdu 10kw 3-phase Metered 200208240v 42
PDU TypeMonitored Output Capacity Details10kW (240V), 9.6kW (230V), 9.1kW (220V), 8.6kW (208V), 8.3kW (200V) total capacity, 13.9A max per breakered outlet bank 12A max per C13 outlet Frequency Compatibility50 / 60 Hz Output Receptacles(42) C13, (6) C19 Output Nominal Voltage200, 208, 240 Overload Protection3 20A circuit breakers, one per output load bank PDU Input Voltage200, 208, 240 Recommended Electrical Service30A 208/240V with L15-30R outlet Maximum Input Amps24 PDU Plug TypeNEMA L15-30P Input Cord Length (m) 1.8 Input Phase3-Phase Reported Load SegmentsReports input current per phase (L1, L2, L3) and output current for each breakered load bank (13.9A balanced max per banks B1-B3), Outlets are color-coded and labelled for phase and load bank identification L1-L2 feeds black outlets (B1), L2-L3 feeds dark-gray outlets (B2), L3-L1 feeds light-gray outlets (B3) Front Panel LCD DisplayLarge digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature and Humidity information (requires ENIVIROSENSE option), Small digital display provides detail on the measurement the large display is reporting: Input-phase (L), Load bank (B), Sensor (S), Load unbalance (UB), Output power (OP) Front Panel LEDsSet of 6 LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage (%UB), Temperature (T), Humidity (%RH) One additional LED for each output load bank (B1-B3) offers information power availablity: GREEN (<80% load), YELLOW(>80% load), RED (Power OFF), RED FLASHING (Power OFF/breaker trip) SwitchesSet of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options, Additional MODE button advances the LEDs to view the next measurement Material of ConstructionMetal Form Factors SupportedVertical rackmount installation supported with included mounting brackets, supports tooless mounting in button-mount compatible racks PDU Form FactorVertical (0U) Operating Temperature Range32 to 122F (0 to 50C)
- Manufacturer:
- Model Number:
- Condition:
- Weight:
- Dimensions:
- Updated:
- Added:
- Tripp Lite
- PDU3VN6L1530B
- New
- 1.00lbs
- 7 X 76 X 10
- Dec 05, 2024
- Jul 25, 2020
Request For Quote.
Tripp PDU3VN6L1530B Tripp-lite Pdu 10kw 3-phase Metered 200208240v 42xc136xc19 Retail