Cart Empty
Tripp SU20KX , Ups, Smartonline 20,000va, Tower, 3-phase Hardwire, 16000w, Expandable
Make an offer
Tripp SU20KX , Ups, Smartonline 20,000va, Tower, 3-phase Hardwire, 160
OUTPUT
Output Volt Amp Capacity (VA):20000
Output kVA capacity (kVA):20
Output Watt Capacity (watts):16000
Output kW capacity:16
Output power factor:0.8 Crest Factor:3:1
Nominal Output Voltage(s) Supported:220/380V 230/400V 240/415V 3-Phase Wye
Frequency compatibility:50 / 60 Hz
Output voltage regulation (line mode):+/- 2%
Output voltage regulation (Battery mode):+/- 2%
Output AC waveform (AC mode):Sine wave
Output AC waveform (battery mode):Pure Sine wave INPUT
Rated input current (at maximum load):24A/25A/26A
Nominal Input Voltage(s) Supported:220/380 - 230/400 - 240/415V AC 3 phase wye
UPS input connection type:Hardwire
UPS input connection description:220/380V, 230/400V or 240/415V , 3-phase, 4-wire + ground, wye BATTERY
Full load runtime (minutes):5.5 min. (16kw)
Half load runtime (minutes):13 min. (8kw)
Expandable battery runtime:Supports extended runtime with optional external battery packs External battery pack compatibility:BP480V26B BP480V40C BP480V55 BP480V78 BP480V103 BP480V140
Expandable runtime description:External battery pack wiring is contractor supplied
DC system voltage (VDC):240
Replacement battery cartridge (internal UPS battery replacement):SURBC2030
Battery replacement description:Hot-swappable, replaceable batteries VOLTAGE REGULATION
Voltage regulation description:Online, double-conversion power conditioning
Overvoltage correction:Maintains continuous operation without using battery power during overvoltages to 276-477 (3-phase, 4-wire, wye), reducing output within 1% of nominal
Undervoltage correction:Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300 (3-phase, 4-wire, wye) LEDS ALARMS and SWITCHES
LED Indicators:4-LED Display: Displays normal AC input, on battery power, bypass input and fault conditions
Alarms:Alarms signal a variety of operational conditions: low-battery, overload, shutdown, bypass and more Alarm cancel operation:Power-fail alarm can be silenced using alarm-cancel switch
Switches:ON button turns UPS inverter on. OFF button turns UPS inverter off. LCD Display Control Buttons browse through and select items displayed on LCD screen. EPO (Emergency Power Off) button turns UPS output off and disables Bypass output SURGE / NOISE SUPPRESSION
UPS AC suppression joule rating:5950
UPS AC suppression response time:Instantaneous
EMI / RFI AC noise suppression:Yes
AC suppression joule rating:5950
AC suppression response time:Instantaneous Installation form factors supported with included accessories
Tower
Primary form factor
Tower
UPS housing material
Steel
Cooling method
Fans
COMMUNICATIONS
Communications interface:DB9 Serial Slot for SNMP/Web interface
PowerAlert software:Included
Communications cable:DB9 cabling included LINE / BATTERY TRANSFER
Transfer time:No transfer time (0 ms.) in online, double-conversion mode
Low voltage transfer to battery power (setpoint):Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300V AC (3-phase, 4-wire, wye). Below this point, output is maintained utilizing reserve battery power High voltage transfer to battery power (setpoint):Maintains continuous operation without using battery power during overvoltages to 276-477V AC (3-phase, 4-wire, wye), reducing output within 1% of nominal. Above this point, output is maintained utilizing reserve battery power SPECIAL FEATURES
Cold Start (startup in battery mode during a power failure):Cold-start operation supported
High availability UPS features:Automatic inverter bypass Hot swappable batteries
Green and high efficiency features:High efficiency economy mode operation Schedulable daily hours of economy mode operation Item Dimension (L"xW"xH"):
55 x 28.5 x 42.5
Weight:
738.5 lb
Warranty Information:
2-year limited warranty
Output Volt Amp Capacity (VA):20000
Output kVA capacity (kVA):20
Output Watt Capacity (watts):16000
Output kW capacity:16
Output power factor:0.8 Crest Factor:3:1
Nominal Output Voltage(s) Supported:220/380V 230/400V 240/415V 3-Phase Wye
Frequency compatibility:50 / 60 Hz
Output voltage regulation (line mode):+/- 2%
Output voltage regulation (Battery mode):+/- 2%
Output AC waveform (AC mode):Sine wave
Output AC waveform (battery mode):Pure Sine wave INPUT
Rated input current (at maximum load):24A/25A/26A
Nominal Input Voltage(s) Supported:220/380 - 230/400 - 240/415V AC 3 phase wye
UPS input connection type:Hardwire
UPS input connection description:220/380V, 230/400V or 240/415V , 3-phase, 4-wire + ground, wye BATTERY
Full load runtime (minutes):5.5 min. (16kw)
Half load runtime (minutes):13 min. (8kw)
Expandable battery runtime:Supports extended runtime with optional external battery packs External battery pack compatibility:BP480V26B BP480V40C BP480V55 BP480V78 BP480V103 BP480V140
Expandable runtime description:External battery pack wiring is contractor supplied
DC system voltage (VDC):240
Replacement battery cartridge (internal UPS battery replacement):SURBC2030
Battery replacement description:Hot-swappable, replaceable batteries VOLTAGE REGULATION
Voltage regulation description:Online, double-conversion power conditioning
Overvoltage correction:Maintains continuous operation without using battery power during overvoltages to 276-477 (3-phase, 4-wire, wye), reducing output within 1% of nominal
Undervoltage correction:Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300 (3-phase, 4-wire, wye) LEDS ALARMS and SWITCHES
LED Indicators:4-LED Display: Displays normal AC input, on battery power, bypass input and fault conditions
Alarms:Alarms signal a variety of operational conditions: low-battery, overload, shutdown, bypass and more Alarm cancel operation:Power-fail alarm can be silenced using alarm-cancel switch
Switches:ON button turns UPS inverter on. OFF button turns UPS inverter off. LCD Display Control Buttons browse through and select items displayed on LCD screen. EPO (Emergency Power Off) button turns UPS output off and disables Bypass output SURGE / NOISE SUPPRESSION
UPS AC suppression joule rating:5950
UPS AC suppression response time:Instantaneous
EMI / RFI AC noise suppression:Yes
AC suppression joule rating:5950
AC suppression response time:Instantaneous Installation form factors supported with included accessories
Tower
Primary form factor
Tower
UPS housing material
Steel
Cooling method
Fans
COMMUNICATIONS
Communications interface:DB9 Serial Slot for SNMP/Web interface
PowerAlert software:Included
Communications cable:DB9 cabling included LINE / BATTERY TRANSFER
Transfer time:No transfer time (0 ms.) in online, double-conversion mode
Low voltage transfer to battery power (setpoint):Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300V AC (3-phase, 4-wire, wye). Below this point, output is maintained utilizing reserve battery power High voltage transfer to battery power (setpoint):Maintains continuous operation without using battery power during overvoltages to 276-477V AC (3-phase, 4-wire, wye), reducing output within 1% of nominal. Above this point, output is maintained utilizing reserve battery power SPECIAL FEATURES
Cold Start (startup in battery mode during a power failure):Cold-start operation supported
High availability UPS features:Automatic inverter bypass Hot swappable batteries
Green and high efficiency features:High efficiency economy mode operation Schedulable daily hours of economy mode operation Item Dimension (L"xW"xH"):
55 x 28.5 x 42.5
Weight:
738.5 lb
Warranty Information:
2-year limited warranty
- Manufacturer:
- Model Number:
- Condition:
- Weight:
- Dimensions:
- Updated:
- Added:
- Tripp Lite
- SU20KX
- New
- 45.00lbs
- 21 X 46 X 34
- Jun 28, 2024
- Mar 04, 2020