Tripp SU8000RT3UN50 , Ups, Smartonline 8000va, 7200w, 6u, 200-240v, L6-30r, L6-20r, Usb, Db9, Epo
Make an offer
Tripp SU8000RT3UN50 , Ups, Smartonline 8000va, 7200w, 6u, 200-240v, L6
OUTPUT
Output Volt Amp Capacity (VA)
8000
Output kVA capacity (kVA)
8 Output kW capacity
7.2
Output Watt Capacity (watts)
7200
Output kW capacity
7.2
Output power factor
0.9
Output Capacity Details
Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power Double conversion mode is automatically restored as load levels are reduced to 95% or less
Nominal Output Voltage(s) Supported
208V 240V
Nominal Voltage details
Voltage selection via front panel LCD interface
Frequency compatibility
50/60 Hz (auto-selectable)
Frequency compatibility details
Output frequency matches input nominal on startup Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
Output voltage regulation (line mode)
+/- 2%
Output voltage regulation (Economy line mode)
+/- 10%
Output voltage regulation (Battery mode)
+/- 2%
Built-in UPS output receptacles
4 L6-20R outlet(s) 2 L6-30R outlet(s)
Output circuit breaker
20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlets each
Basic PDU options
PDU1230 (1U / 2 C19, 16 C13 outlets) PDUNV (1U / 2 C19, 12 C13 outlets) PDUV30HV (0U / 6 C19, 32 C13 outlets)
Metered PDU options
PDUMV20HV (0U / 6 C19, 32 C13 outlets)
PDUMV30HV (0U / 6 C19, 24 C13 outlets)
Monitored PDU options
PDUMNV20HV (0U / 4 C19, 20 C13 outlets)
PDUMNV30HV (0U / 4 C19, 20 C13 outlets)
Switched PDU options
PDUMH20HVNET (1U / 8 C13 outlets)
PDUMH30HVNET (2U / 16 C13 outlets)
PDUMV20HVNET (0U / 4 C19, 24 C13 outlets)
PDUMV30HVNET (0U / 4 C19, 24 C13 outlets)
Output AC waveform (AC mode)
Pure Sine wave
Output AC waveform (battery mode)
Pure Sine wave
INPUT
Rated input current (at maximum load)
44.2A (208V), 38.3A (240V)
Nominal Input V UPS input connection type
Hubbell CS8265 Hardwire
oltage(s) Supported
208V AC 240V AC
UPS input connection description
3 wire single phase input (L1, L2, G)
Recommended Electrical Service
208/240V 50A
BATTERY
Full load runtime (minutes)
5.5 min. (7200w)
Half load runtime (minutes)
13.5 min. (3600w)
Expandable battery runtime
Supports extended runtime with optional external battery packs
External battery pack compatibility
BP240V10RT3U BP240V557C-1PH BP240V787C-1PH BP240V1037C-1PH BP240V1407C-1PH
DC system voltage (VDC)
240
Battery recharge rate (included batteries)
Less than 6 hours from 10% to 90%
Battery replacement description
Hot-swappable, user replaceable external battery packs
VOLTAGE REGULATION
Voltage regulation description
2% output voltage regulation in standard online, double-conversion mode
Overvoltage correction
Corrects overvoltages up to 300V
Undervoltage correction
Corrects undervoltages as low as 100V
LEDS ALARMS SWITCHES
LED Indicators
6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status LCD screen offers additional information and control options
Front panel LCD display
Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options LED/LCD panel rotates for viewing in rack/tower formats (see manual)
Alarms
Unique audible alarms for all major UPS, environmental and power conditions (see manual)
Alarm cancel operation
Alarm cancel switch
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation 2 additional switches support set and execute scrolling LCD functions bundled PDU includes bypass switch to enable hot-swap UPS power module replacement
SURGE / NOISE SUPPRESSION
UPS AC suppression response time
Instantaneous
EMI / RFI AC noise suppression
Yes
PHYSICAL
Installation form factors supported with included accessories
Tower
Included mounting accessory description
2 sets of adjustable 4 post rack rails included 2-9USTAND tower kit included (supports up to 9U in tower format)
Installation form factors supported with optional accessories
2 post rackmount (2POSTRMKITHD)
Optional mounting accessory notes
2 sets of 2POSTRMKITHD required for 2 post rackmount installation of separate power module and battery pack
Primary form factor
Rackmount
Installed whole system total rack space height (rack spaces)
6U
Secondary form factor
Tower
UPS housing material
Steel
Cooling method
Fan
ENVIRONMENTAL
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 Operating Elevation (ft)
0-3000m (0 to 10,000 ft.)
degrees Celsius
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC mode BTU / hr. (full load)
2732
AC economy mode BTU / hr. (full load)
1020
AC economy mode efficiency rating (100% load)
96%
Operating Elevation (ft)
0-3000m (0 to 10,000 ft.)
Audible Noise
60 dBA at front side 1 meter
COMMUNICATIONS
Communications interface
USB (HID enabled) DB9 Serial EPO (emergency power off) Slot for SNMP/Web interface PowerAlert software
Included
Network monitoring port description
Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
PowerAlert software
Included
Communications cable
USB, DB9 serial and EPO cables included
WatchDog compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer time
No transfer time (0 ms.) in online, double-conversion mode
Transfer time (economy mode)
8 ms. typical power failure response in optional economy mode
Low voltage transfer to battery power (setpoint)
100V
High voltage transfer to battery power (setpoint)
300V
SPECIAL FEATURES
Cold Start (startup in battery mode during a power failure)
Cold-start operation supported
Economy mode operation
Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.
High availability UPS features
Automatic inverter bypass Manual bypass switch Detachable hot-swap PDU Hot swappable UPS power module Hot swappable batteries
Green high efficiency features
High efficiency economy mode operation Schedulable daily hours of economy mode operation
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA) Tested to CSA (Canada) Tested to NOM (Mexico) Tested to CE (EU) Meets FCC Part 15 Category A (EMI)
UPS Certification details
IEC 61000-4-5 1995 B Surge Immunity
Item Dimension (L"xW"xH")
31.5 x 23 x 37 Weight
302.56 Warranty
250,000 connected equipment insurance (U.S., Canada Puerto Rico)
Output Volt Amp Capacity (VA)
8000
Output kVA capacity (kVA)
8 Output kW capacity
7.2
Output Watt Capacity (watts)
7200
Output kW capacity
7.2
Output power factor
0.9
Output Capacity Details
Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power Double conversion mode is automatically restored as load levels are reduced to 95% or less
Nominal Output Voltage(s) Supported
208V 240V
Nominal Voltage details
Voltage selection via front panel LCD interface
Frequency compatibility
50/60 Hz (auto-selectable)
Frequency compatibility details
Output frequency matches input nominal on startup Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
Output voltage regulation (line mode)
+/- 2%
Output voltage regulation (Economy line mode)
+/- 10%
Output voltage regulation (Battery mode)
+/- 2%
Built-in UPS output receptacles
4 L6-20R outlet(s) 2 L6-30R outlet(s)
Output circuit breaker
20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlets each
Basic PDU options
PDU1230 (1U / 2 C19, 16 C13 outlets) PDUNV (1U / 2 C19, 12 C13 outlets) PDUV30HV (0U / 6 C19, 32 C13 outlets)
Metered PDU options
PDUMV20HV (0U / 6 C19, 32 C13 outlets)
PDUMV30HV (0U / 6 C19, 24 C13 outlets)
Monitored PDU options
PDUMNV20HV (0U / 4 C19, 20 C13 outlets)
PDUMNV30HV (0U / 4 C19, 20 C13 outlets)
Switched PDU options
PDUMH20HVNET (1U / 8 C13 outlets)
PDUMH30HVNET (2U / 16 C13 outlets)
PDUMV20HVNET (0U / 4 C19, 24 C13 outlets)
PDUMV30HVNET (0U / 4 C19, 24 C13 outlets)
Output AC waveform (AC mode)
Pure Sine wave
Output AC waveform (battery mode)
Pure Sine wave
INPUT
Rated input current (at maximum load)
44.2A (208V), 38.3A (240V)
Nominal Input V UPS input connection type
Hubbell CS8265 Hardwire
oltage(s) Supported
208V AC 240V AC
UPS input connection description
3 wire single phase input (L1, L2, G)
Recommended Electrical Service
208/240V 50A
BATTERY
Full load runtime (minutes)
5.5 min. (7200w)
Half load runtime (minutes)
13.5 min. (3600w)
Expandable battery runtime
Supports extended runtime with optional external battery packs
External battery pack compatibility
BP240V10RT3U BP240V557C-1PH BP240V787C-1PH BP240V1037C-1PH BP240V1407C-1PH
DC system voltage (VDC)
240
Battery recharge rate (included batteries)
Less than 6 hours from 10% to 90%
Battery replacement description
Hot-swappable, user replaceable external battery packs
VOLTAGE REGULATION
Voltage regulation description
2% output voltage regulation in standard online, double-conversion mode
Overvoltage correction
Corrects overvoltages up to 300V
Undervoltage correction
Corrects undervoltages as low as 100V
LEDS ALARMS SWITCHES
LED Indicators
6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status LCD screen offers additional information and control options
Front panel LCD display
Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options LED/LCD panel rotates for viewing in rack/tower formats (see manual)
Alarms
Unique audible alarms for all major UPS, environmental and power conditions (see manual)
Alarm cancel operation
Alarm cancel switch
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation 2 additional switches support set and execute scrolling LCD functions bundled PDU includes bypass switch to enable hot-swap UPS power module replacement
SURGE / NOISE SUPPRESSION
UPS AC suppression response time
Instantaneous
EMI / RFI AC noise suppression
Yes
PHYSICAL
Installation form factors supported with included accessories
Tower
Included mounting accessory description
2 sets of adjustable 4 post rack rails included 2-9USTAND tower kit included (supports up to 9U in tower format)
Installation form factors supported with optional accessories
2 post rackmount (2POSTRMKITHD)
Optional mounting accessory notes
2 sets of 2POSTRMKITHD required for 2 post rackmount installation of separate power module and battery pack
Primary form factor
Rackmount
Installed whole system total rack space height (rack spaces)
6U
Secondary form factor
Tower
UPS housing material
Steel
Cooling method
Fan
ENVIRONMENTAL
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 Operating Elevation (ft)
0-3000m (0 to 10,000 ft.)
degrees Celsius
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC mode BTU / hr. (full load)
2732
AC economy mode BTU / hr. (full load)
1020
AC economy mode efficiency rating (100% load)
96%
Operating Elevation (ft)
0-3000m (0 to 10,000 ft.)
Audible Noise
60 dBA at front side 1 meter
COMMUNICATIONS
Communications interface
USB (HID enabled) DB9 Serial EPO (emergency power off) Slot for SNMP/Web interface PowerAlert software
Included
Network monitoring port description
Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
PowerAlert software
Included
Communications cable
USB, DB9 serial and EPO cables included
WatchDog compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer time
No transfer time (0 ms.) in online, double-conversion mode
Transfer time (economy mode)
8 ms. typical power failure response in optional economy mode
Low voltage transfer to battery power (setpoint)
100V
High voltage transfer to battery power (setpoint)
300V
SPECIAL FEATURES
Cold Start (startup in battery mode during a power failure)
Cold-start operation supported
Economy mode operation
Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.
High availability UPS features
Automatic inverter bypass Manual bypass switch Detachable hot-swap PDU Hot swappable UPS power module Hot swappable batteries
Green high efficiency features
High efficiency economy mode operation Schedulable daily hours of economy mode operation
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA) Tested to CSA (Canada) Tested to NOM (Mexico) Tested to CE (EU) Meets FCC Part 15 Category A (EMI)
UPS Certification details
IEC 61000-4-5 1995 B Surge Immunity
Item Dimension (L"xW"xH")
31.5 x 23 x 37 Weight
302.56 Warranty
250,000 connected equipment insurance (U.S., Canada Puerto Rico)
- Manufacturer:
- Model Number:
- Condition:
- Weight:
- Dimensions:
- Updated:
- Added:
- Tripp Lite
- SU8000RT3UN50
- New
- 302.56lbs
- 32 X 37 X 23
- Jun 28, 2024
- Mar 04, 2020