Cart Empty
Tripp SMART1050NET Smartpro 120v 1.05kva 705w Line-interactive Ups Tower Usb 6 Outlets
Make an offer
Tripp SMART1050NET Smartpro 120v 1.05kva 705w Line-interactive Ups To
Voltage compatibility - 120V AC , Frequency compatibility - 60Hz Output volt amp capacity (VA) - 1050 , Output watt capacity (watts) - 705 , Output nominal voltage - 120V AC Output voltage regulation - LINE MODE---Sine wave line voltage 120V (below 18 percent or above 8 percent) , BATTERY MODE---PWM sine wave output 120V above or below 0.5Hz Output frequency regulation - LINE MODE---Passes line frequency of 60Hz above or below 10 percent , BATTERY MODE---Inverter output regulated to 60Hz above or below 0.5Hz Outlet quantity / type - 6 NEMA 5-15R Overload protection - 12A input breaker Maximum input amps - 6.7A /760 watts Input connection type - NEMA 5-15P Input cord length - 6 ft., 16 gauge Recommended electrical service - 15A 120V BATTERY - Full load runtime---8 minutes (1050VA) , Half load runtime---23 minutes (525VA) , DC system voltage---18 VDC , Typical battery lifespan---3-6 years, depending on usage , Battery recharge rate---2-4 hours to 90 percent Voltage regulation description - Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 75V and overvoltages to 147V Overvoltage correction - Input voltages between 128 and 147VAC are reduced by 12 percent Direct pass through - Input voltages between 108 and 127VAC are passed on to connected equipment unchanged Brownout correction - Input voltages between 108 and 127VAC are passed on to connected equipment unchanged Severe brownout correction - Input voltages between 75 and 92VAC are boosted by 30 percent Front panel LEDs - Includes 5 front panel LEDs to indicate BATTERY CHARGE LEVEL, AC LINE POWER STATUS, VOLTAGE REGULATION STATUS, UPS LOAD LEVEL and BATTERY LOW / REPLACE information Alarms - Audible alarm with 15 second delay sounds to indicate loss of utility power. Alarm can be silenced by pressing front panel alarm cancel button. Once silenced, alarm will re-sound when approximately 2 minutes runtime remain. Switches - Includes 2 front panel switches--one main on/off power switch and one dual function alarm cancel / self test button AC surge suppression - 480 joules
- Manufacturer:
- Model Number:
- Condition:
- Weight:
- Dimensions:
- Updated:
- Added:
- Tripp Lite
- SMART1050NET
- New
- 29.10lbs
- 7 X 12 X 7
- Jun 28, 2024
- Mar 04, 2020
Request For Quote.
Tripp SMART1050NET Smartpro 120v 1.05kva 705w Line-interactive Ups Tower Usb 6 Outlets