Cart Empty
Tripp PDUMH15HVATNET Pdu Switched Ats 22.4kw 200240v 10 C13 2 C14 3.6m Cords 1urm
Make an offer
General Information2-2.4kW Single-Phase ATS PDU with Primary and Secondary Inputs for Power RedundancyRecommended for data centers, server rooms and network closets, this 1U switched power distribution unit enables redundant A/B power for network devices with single power cords. Dual 12-foot (3.7-meter) input cords with C14 plugs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids. Plug-lock insert sleeves are included to prevent connected cords from becoming accidentally dislodged. The PDUMH15HVATNET constantly evaluates the power quality of both input sources and maintains continuous power to all outlets as derived from the primary source.Switches from Primary to Secondary Power Source in MillisecondsDynamic solid-state automatic transfer switching (ATS) allows the IEC C13 PDU to switch to the secondary source within 2-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor prevents switching if the secondary source is unavailable or of lower quality than the primary source.Switched C13 Outlets Are Individually Controllable for Remote Reboots and Load Shedding This switched power distribution unit distributes, monitors and manages selectable 200-240V power to equipment in network applications requiring individual outlet control, load shedding and remote monitoring of critical network components. Eight switched C13 outlets (two additional C13 outlets are unswitched) are subject to advanced network control and remote power monitoring, including the ability to turn on, turn off, reboot or lock out power to each outlet. Reducing the frequency of on-site visits can save you money and reduce downtime, thus lowering the PDU's total cost of ownership. Check Essential Functions at a GlanceA front-panel digital load meter displays total PDU output current in amps. LEDs indicate on/off status of individual outlets and power status of primary and secondary inputs. An input-voltage select switch lets you toggle between high (220, 230 or 240V) or low (200 or 208V) voltage.Built-In LX Platform Interface Gives You Unrestricted Remote Access to Your Equipment 24/7The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.Reduce Service Calls with Auto Probe Autonomous Device Management The Auto Probe feature (Firmware 15.5.2 and greater) checks the connectivity status of any networked device and automatically takes one or more user-configured actions if the device fails to respond; actions include outlet reboot, set SNMP traps, SNMP OID sets, and even script execution when used in conjunction with the Tripp Lite PowerAlert Network Shutdown Agent (PANSA).Easy to Install Horizontally in an EIA-Standard 19 in. RackThis ATS PDU mounts in 1U of space in 19-inch rack or rack cabinet using the included brackets and hardware.TAA-Compliant for GSA Schedule PurchasesThe PDUMH15HVATNET is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.Technical InformationInput Receptacles: 2 x IEC 60320 C14Output Receptacles: 10 x IEC 60320 C13Protection Type: Overload Protection
General InformationThe PDUMH15HVATNET 2-2.4kW Single-Phase 200-240V ATS/Switched PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features eight switched and two unswitched C13 outlets.Dual 3.6-meter input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources in a nominal voltage range from 200-240V. Plug lock inserts prevent cords from accidental disconnection. The PDUMH15HVATNET constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 2-5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Supports user-programmable startup of outlets in any order or interval to ensure network items are turned on in the proper sequence and reliably discovered. Digital ammeter monitors total output current. LEDs display outlet on/off status and input power status on primary and secondary inputs. Connecting the optional ENVIROSENSE module (sold separately) lets you remotely monitor temperature and humidity.Additional Product SpecificationsFull Product Specifications: Click to viewTechnical InformationInput Receptacles: 2 x IEC 60320 C14Output Receptacles: 10 x IEC 60320 C13Protection Type: Overload ProtectionPower DescriptionInput Voltage: 200 V ACInput Voltage: 208 V ACInput Voltage: 220 V ACInput Voltage: 230 V ACInput Voltage: 240 V ACOutput Voltage: 200 V ACOutput Voltage: 208 V ACOutput Voltage: 220 V ACOutput Voltage: 230 V ACOutput Voltage: 240 V ACPower Rating: 2400 VAInput Current: 10 AManagementManagement: HTTP HTTPSPowerAlert SMTP SNMPv1 SNMPv2 SNMPv3 Telnet SSH FTP DHCP BOOTP and NTP protocols Interfaces/PortsNetwork (RJ-45): YesPhysical CharacteristicsForm Factor: Horizontal RackmountRack Height: 1U/2UHeight: 1.7"Width: 17.3"Depth: 14.4"Weight (Approximate): 10.41 lbMiscellaneousPackage Contents: PDUMH15HVATNET 10-Outlet PDU 10 x C14 plug lock inserts 2 x C13 to C14 power cords, 3.6 m (11.8 ft.) SNMPWEBCARD configuration cable 2 x Mounting brackets, horizontal 2 x Mounting brackets, vertical 6 x Screws Owner's manual Environmentally Friendly: YesEnvironmental Certification: RoHSWarrantyLimited Warranty: 2 Year
- Manufacturer:
- Model Number:
- Condition:
- Weight:
- Dimensions:
- Updated:
- Added:
- Country of Origin:
- Tripp Lite
- PDUMH15HVATNET
- New
- 10.40lbs
- 23 X 6 X 21
- Dec 18, 2024
- Mar 01, 2020
- Taiwan
Request For Quote.
Tripp PDUMH15HVATNET Pdu Switched Ats 22.4kw 200240v 10 C13 2 C14 3.6m Cords 1urm