Received! Our sales team will contact you soon.

Tripp SUINT3000RTXL2U , Ups, Smartonline 3000va, 2500w, 2u, 200-240v, C13 And C19 Outlets, Usb, Db9, Epo

Make an offer
Out of Stock / 3 Sold

Special Price $1813.56 Regular Price $2448.31

Condition: New
Tripp Lite
TRIPP LITE
Free Shipping for this Item


General Information3000VA / 3kVA / 2500 watt on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an installed depth of only 66cm (26 inches). Full time sine wave 200/208/220/230/240V output with +/-2% voltage regulation. UPS actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 120V and overvoltages to 288V. C20 inlet accepts a wide variety of optional cordsets. C19 and C13 output receptacles. Network management interfaces include USB port, DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Multi-stage metered current monitoring and battery charge status LEDs.Technical InformationReceptacles: 10Bypass Switch: AutomaticEmergency Power OFF: YesTransfer Time: 0 nsPower DescriptionLoad Capacity: 3000 VA/2500 WInput Voltage: 220 V ACOutput Voltage: 240 V ACOutput Voltage: 208 V ACOutput Voltage: 220 V ACOutput Voltage: 230 V ACInput Current: 15 AManagementNetwork Management: SNMP ManageableInterfaces/PortsSerial Port: YesUSB: YesBattery InformationBackup/Run Time (Full Load): 6 MinuteBackup/Run Time (Half Load): 15 MinuteTypical Battery Recharge Time: 4.80 HourHot Swappable: YesPhysical CharacteristicsHeight: 3.5"Width: 17.3"Depth: 26"Rack Height: 2UForm Factor: Rack/TowerWeight (Approximate): 78.30 lbMiscellaneousPackage Contents: SmartOnline SUINT3000RTXL2U 3000 VA Tower/Rack Mountable UPS4 Post Rackmount Installation BracketsC19 to C20 Power CablePowerAlert Software CDUSB CableSerial CableOwner's Manual with Warranty InformationAdditional Information: Input Receptacle: C20Output Receptacles: 2 x C198 x C13Certifications & Standards: UL1778FCC Part 15 Category A (EMI)TAA CompliantSoftware Included: PowerAlert SoftwareEnvironmentally Friendly: YesEnvironmental Certification: RoHSWarrantyLimited Warranty: 2 Year

OUTPUT
Output Volt Amp Capacity (VA)
3000
Output kVA Capacity (kVA)
3
Output Watt Capacity (Watts)
2500
Output kW Capacity (kW)
2.5
Power Factor
0.83
Crest Factor
3:1
Nominal Voltage Details
230V default
Frequency Compatibility
50 / 60 Hz
Frequency Compatibility Details
Output frequency matches input nominal on startup, defaults to 50 Hz on cold-start
Output Voltage Regulation (Line Mode)
+/- 2%
Output Voltage Regulation (Economy Line Mode)
+/-10%
Output Voltage Regulation (Battery Mode)
+/- 2%
Included Output Power Cables
Includes 2 C13 to C14 and 1 C19 to C20 power cables
Load Management Receptacles
Two switchable 4 C13 outlet load banks
Hot-Swap PDU options
PDUBHV20 (2U / 6 C13, 2 C19 outlets)
Output AC Waveform (AC Mode)
Sine wave
Output AC Waveform (Battery Mode)
Pure Sine wave
Output Capacity Details
OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits of 10% and 5Hz) or SHUTDOWN (when bypass input voltage and frequency are OUTSIDE bypass limits of 10% and 5Hz)
Nominal Output Voltage(s) Supported
200V 220V 230V 240V
Output Receptacles
(8) C13 (2) C19
Individually Controllable Load Banks
Yes
INPUT
Rated input current (Maximum Load)
15A
Nominal Input Voltage(s) Supported
230V AC
Nominal Input Voltage Description
230V factory configuration
UPS Input Connection Type
C20 inlet
UPS Input Cord Length (ft.)
5
UPS Input Cord Length (m)
1.5
Input Phase
Single-Phase
BATTERY
Full Load Runtime (min.)
6 min. (2500w)
Half Load Runtime (min.)
15 min. (1250w)
Expandable Battery Runtime
Supports extended runtime with optional external battery packs
External Battery Pack Compatibility
BP72V15-2U (limit 1) BP72V28RT-3U (multi-pack compatible) BP72V18-2US (multi-pack compatible)
DC System Voltage (VDC)
72
Battery Recharge Rate (Included Batteries)
Less than 4.8 hours from 10% to 90% (typical, full load discharge)
Internal UPS Replacement Battery Cartridge
See RBC selector
Battery Access
Front panel battery access door
Battery Replacement Description
Hot-swappable, replaceable batteries
Expandable Runtime
Yes
VOLTAGE REGULATION
Voltage Regulation Description
Online, double-conversion power conditioning
Overvoltage Correction
2% output voltage regulation during overvoltages to 288
Undervoltage Correction
2% output voltage regulation during undervoltages to 160V (70-100% load) / 130V (30-70% load) / 100V (Under 30% load)
USER INTERFACE, ALERTS CONTROLS
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation
Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm
Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation
LED Indicators
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information 4-LED meter displays load and battery charge levels LED panel rotates for viewing in rack/tower formats
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
570
EMI / RFI AC Noise Suppression
Yes
AC Suppression Response Time
Instantaneous
PHYSICAL
Installation Form Factors Supported with Included Accessories
4 post 19 inch rackmount
Included Mounting Accessory Description
Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
Installation Form Factors Supported with Optional Accessories
2 post rackmount (2POSTRMKITWM) 2-4 post front rail rackmount (UPSHDEARKIT) 4 post rackmount short-depth (4POSTRAILKITWM) Tower (2-9USTAND) Wallmount (2POSTRMKITWM)
Optional Mounting Accessory Notes
Optional 2-9USTAND enables upright tower UPS placement 2POSTRMKITWM enables wall-mount and 2-post rackmount installation 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm) UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support
Primary Form Factor
Rackmount
UPS Power Module Dimensions (hwd, cm)
8.79 x 43.79 x 61.60
Rack Height
2U
Cooling Method
Fan
UPS Housing Material
Steel
ENVIRONMENTAL
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
Relative Humidity
5 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)
742
AC Mode Efficiency Rating (100% Load)
92%
COMMUNICATIONS
Communications Interface
USB (HID enabled) DB9 Serial Contact closure EPO (emergency power off) Slot for SNMP/Web interface
Network Management Cards
WEBCARDLX
Network Monitoring Port Description
Supports detailed monitoring of UPS and site power conditions DB9 port supports RS232 and contact closure communications
PowerAlert Software
For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable
USB and DB9 cabling included
WatchDog Compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time
No transfer time (0 ms.) in online, double-conversion mode
Low Voltage Transfer to Battery Power (Setpoint)
160V (70-100% load), 130V (30-70% load), 100V (less than 33% load)
High Voltage Transfer to Battery Power (Setpoint)
288V
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure)
Cold-start operation supported
High Availability UPS Features
Automatic inverter bypass Hot swappable batteries
Green Energy-Saving Features
High efficiency economy mode operation Individually controllable load banks
CERTIFICATIONS
UPS Certifications
CE
UPS Certification Details
Agency standard tested: IEC62040-1:2008+A1 EMI approvals: EN62040-2:2006
Item Dimension ( L inchxW inchxH inch)
25 x 18 x 4 Weight
84.7 lb Warranty Information
2-year limited warranty
  • Manufacturer:
  • Model Number:
  • Condition:
  • Weight:
  • Dimensions:
  • Updated:
  • Added:
  • Tripp Lite
  • SUINT3000RTXL2U
  • New
  • 70.55lbs
  • 32 X 9 X 22
  • Sep 21, 2024
  • Feb 29, 2020

Request For Quote.


Tripp SUINT3000RTXL2U , Ups, Smartonline 3000va, 2500w, 2u, 200-240v, C13 And C19 Outlets, Usb, Db9, Epo

Write a Review