Tripp PDU3VN6G60B Upc 3-phase Monitored Pdu 14.5kw 240v Outlets Retail
Make an offer
Tripp PDU3VN6G60B Upc 3-phase Monitored Pdu 14.5kw 240v Outlets Retai
PDU Type
Monitored Output Capacity
Details 14.5kW (240V), 13.9kW (230V), 13.3kW (220V), 12.6kW (208V), 12.1kW (200V) total capacity 20A max per breakered outlet bank 16A max per C19 outlet 12A max per C13 outlet Frequency Compatibility
50 / 60 Hz Output Receptacles
(42) C13, (6) C19 Output Nominal Voltage
200, 208, 240 Overload Protection
3 20A circuit breakers, 1 per outlet bank PDU Input Voltage
200, 208, 240 Recommended Electrical Service
60A 208/240V with IEC309 60A Blue (3P+E) outlet Maximum Input Amps
35 PDU Plug Type
IEC-309 60A BLUE (3P+E) Input Cord Length (m)
1.8 Input Phase
3-Phase Reported Load Segments
Reports input current per phase (L1, L2, L3) and output current for each breakered load bank (20A balanced max per banks B1-B3), Outlets are color-coded and labelled for phase and load bank identification, L1-L2 feeds black outlets (B1), L2-L3 feeds dark-gray outlets (B2) L3-L1 feeds light-gray outlets (B3) Front Panel LCD Display
Large digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature and Humidity information (requires ENIVIROSENSE option) Small digital display provides detail on the measurement the large display is reporting: Input-phase (L), Load bank (B), Sensor (S), Load unbalance (UB), Output power (OP) Front Panel LEDs
Set of 6 LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage ( percent UB), Temperature (T), Humidity (percent RH), One additional LED for each output load bank (B1-B3) offers information power availablity: GREEN (<80 percent load), YELLOW (>80 percent load), RED (Power OFF), RED FLASHING (Power OFF/breaker trip) Switches
Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options, Additional MODE button advances the LEDs to view the next measurement Material of Construction
Metal Form Factors Supported
Vertical rackmount installation supported with included mounting brackets supports tooless mounting in button-mount compatible racks PDU Form Factor
Vertical (0U) Operating Temperature Range
32 to 122F (0C to 50C)
Monitored Output Capacity
Details 14.5kW (240V), 13.9kW (230V), 13.3kW (220V), 12.6kW (208V), 12.1kW (200V) total capacity 20A max per breakered outlet bank 16A max per C19 outlet 12A max per C13 outlet Frequency Compatibility
50 / 60 Hz Output Receptacles
(42) C13, (6) C19 Output Nominal Voltage
200, 208, 240 Overload Protection
3 20A circuit breakers, 1 per outlet bank PDU Input Voltage
200, 208, 240 Recommended Electrical Service
60A 208/240V with IEC309 60A Blue (3P+E) outlet Maximum Input Amps
35 PDU Plug Type
IEC-309 60A BLUE (3P+E) Input Cord Length (m)
1.8 Input Phase
3-Phase Reported Load Segments
Reports input current per phase (L1, L2, L3) and output current for each breakered load bank (20A balanced max per banks B1-B3), Outlets are color-coded and labelled for phase and load bank identification, L1-L2 feeds black outlets (B1), L2-L3 feeds dark-gray outlets (B2) L3-L1 feeds light-gray outlets (B3) Front Panel LCD Display
Large digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature and Humidity information (requires ENIVIROSENSE option) Small digital display provides detail on the measurement the large display is reporting: Input-phase (L), Load bank (B), Sensor (S), Load unbalance (UB), Output power (OP) Front Panel LEDs
Set of 6 LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage ( percent UB), Temperature (T), Humidity (percent RH), One additional LED for each output load bank (B1-B3) offers information power availablity: GREEN (<80 percent load), YELLOW (>80 percent load), RED (Power OFF), RED FLASHING (Power OFF/breaker trip) Switches
Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options, Additional MODE button advances the LEDs to view the next measurement Material of Construction
Metal Form Factors Supported
Vertical rackmount installation supported with included mounting brackets supports tooless mounting in button-mount compatible racks PDU Form Factor
Vertical (0U) Operating Temperature Range
32 to 122F (0C to 50C)
- Manufacturer:
- Model Number:
- Condition:
- Weight:
- Dimensions:
- Updated:
- Added:
- Tripp Lite
- PDU3VN6G60B
- New
- 25.43lbs
- 7 X 76 X 10
- Jun 28, 2024
- Jul 25, 2020
Request For Quote.
Tripp PDU3VN6G60B Upc 3-phase Monitored Pdu 14.5kw 240v Outlets Retail