Cart Empty
Tripp SMX1000RT2U , Ups, Smartpro 1000va, 230v, 700w, 1u, Intl, Avr, 6 X C13 Outlets, Usb, Db9, Epo
Make an offer
1000VA/900W - 3.6 Minute Full Load - 6 x IEC 320-C13 - Battery/Surge-protected
OUTPUT
Output Volt Amp Capacity (VA):1000
Output kVA capacity (kVA):1
Output Watt Capacity (watts):700
Output power factor:0.7
Nominal Output Voltage(s) Supported:220V 230V 240V
Nominal Voltage details:230v nominal inverter output voltage Frequency compatibility:50 / 60 Hz
Output voltage regulation (line mode):-17%, +8%
Output voltage regulation (Battery mode):+/- 5%
Built-in UPS output receptacles:6 C13 outlet(s)
Included output power cables:Includes 2 C13 to C14 output power cables
Built-in controllable switched load banks:Two switchable two-outlet C13 load banks
Output AC waveform (AC mode):Sine wave
Output AC waveform (battery mode):Pure Sine wave INPUT
Rated input current (at maximum load):3.4A
Nominal Input Voltage(s) Supported:230V AC
UPS input connection type:C14 inlet
UPS input connection description:C14 inlet accepts user-supplied AC power cord with country specific plug.
Input circuit breaker:10A BATTERY
Full load runtime (minutes):9 min. (700w)
Half load runtime (minutes):21 min. (350w)
DC system voltage (VDC):24
Battery recharge rate (included batteries):4.5 hours from 10% to 90%
Replacement battery cartridge (internal UPS battery replacement):RBC92-2U
Battery Access:Front panel battery access door
Battery replacement description:Hot-swappable, user replaceable batteries VOLTAGE REGULATION
Voltage regulation description:Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 159 to 282
Overvoltage correctionInput voltages between 245 and 282 are reduced by 12%
Undervoltage correction:Input voltages between 159 and 199 are boosted by 14% LEDS ALARMS and SWITCHES
LED Indicators5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Alarms:Audible alarm indicates power-failure, overload and low-battery conditions
Alarm cancel operation:Power-fail alarm can be silenced using alarm-cancel switch once silenced, alarm will re-sound to indicate low-battery status
Switches:2 Switches control off/on power status and alarm-cancel/self-test operation SURGE / NOISE SUPPRESSION
UPS AC suppression joule rating480
UPS AC suppression response time:Instantaneous
EMI / RFI AC noise suppression:Yes
UPS housing material
Steel
Cooling method
Fan COMMUNICATIONS
Communications interface:USB DB9 Serial EPO (emergency power off) Slot for SNMP/Web interface
Network monitoring port description:Supports detailed monitoring of UPS and site power conditions
PowerAlert software:Included
Communications cable:USB and DB9 cabling included
WatchDog compatibility:Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER
Transfer time:2-4 milliseconds
Low voltage transfer to battery power (setpoint):159
High voltage transfer to battery power (setpoint):282 SPECIAL FEATURES
Grounding lug:Back panel grounding lug
Cold Start (startup in battery mode during a power failure):Cold-start operation supported
High availability UPS features:Hot swappable batteries
Green and high efficiency features:Greater than 95% efficiency - GREEN UPS Individually controllable load banks CERTIFICATIONS
UPS Certifications:Tested to UL1778 (USA) Tested to CE (EU) Tested to GOST (Russia) Tested to SASO (Saudi Arabia) Tested to IRAM (Argentina) Meets FCC Part 15 Category B (EMI) Item Dimension (L"xW"xH"):
9.5 x 20.25 x 23.5
Weight:
45.8 lb
Warranty Information:
2 Years Limited
Output Volt Amp Capacity (VA):1000
Output kVA capacity (kVA):1
Output Watt Capacity (watts):700
Output power factor:0.7
Nominal Output Voltage(s) Supported:220V 230V 240V
Nominal Voltage details:230v nominal inverter output voltage Frequency compatibility:50 / 60 Hz
Output voltage regulation (line mode):-17%, +8%
Output voltage regulation (Battery mode):+/- 5%
Built-in UPS output receptacles:6 C13 outlet(s)
Included output power cables:Includes 2 C13 to C14 output power cables
Built-in controllable switched load banks:Two switchable two-outlet C13 load banks
Output AC waveform (AC mode):Sine wave
Output AC waveform (battery mode):Pure Sine wave INPUT
Rated input current (at maximum load):3.4A
Nominal Input Voltage(s) Supported:230V AC
UPS input connection type:C14 inlet
UPS input connection description:C14 inlet accepts user-supplied AC power cord with country specific plug.
Input circuit breaker:10A BATTERY
Full load runtime (minutes):9 min. (700w)
Half load runtime (minutes):21 min. (350w)
DC system voltage (VDC):24
Battery recharge rate (included batteries):4.5 hours from 10% to 90%
Replacement battery cartridge (internal UPS battery replacement):RBC92-2U
Battery Access:Front panel battery access door
Battery replacement description:Hot-swappable, user replaceable batteries VOLTAGE REGULATION
Voltage regulation description:Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 159 to 282
Overvoltage correctionInput voltages between 245 and 282 are reduced by 12%
Undervoltage correction:Input voltages between 159 and 199 are boosted by 14% LEDS ALARMS and SWITCHES
LED Indicators5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Alarms:Audible alarm indicates power-failure, overload and low-battery conditions
Alarm cancel operation:Power-fail alarm can be silenced using alarm-cancel switch once silenced, alarm will re-sound to indicate low-battery status
Switches:2 Switches control off/on power status and alarm-cancel/self-test operation SURGE / NOISE SUPPRESSION
UPS AC suppression joule rating480
UPS AC suppression response time:Instantaneous
EMI / RFI AC noise suppression:Yes
UPS housing material
Steel
Cooling method
Fan COMMUNICATIONS
Communications interface:USB DB9 Serial EPO (emergency power off) Slot for SNMP/Web interface
Network monitoring port description:Supports detailed monitoring of UPS and site power conditions
PowerAlert software:Included
Communications cable:USB and DB9 cabling included
WatchDog compatibility:Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER
Transfer time:2-4 milliseconds
Low voltage transfer to battery power (setpoint):159
High voltage transfer to battery power (setpoint):282 SPECIAL FEATURES
Grounding lug:Back panel grounding lug
Cold Start (startup in battery mode during a power failure):Cold-start operation supported
High availability UPS features:Hot swappable batteries
Green and high efficiency features:Greater than 95% efficiency - GREEN UPS Individually controllable load banks CERTIFICATIONS
UPS Certifications:Tested to UL1778 (USA) Tested to CE (EU) Tested to GOST (Russia) Tested to SASO (Saudi Arabia) Tested to IRAM (Argentina) Meets FCC Part 15 Category B (EMI) Item Dimension (L"xW"xH"):
9.5 x 20.25 x 23.5
Weight:
45.8 lb
Warranty Information:
2 Years Limited
- Manufacturer:
- Model Number:
- Condition:
- Weight:
- Dimensions:
- Updated:
- Added:
- Country of Origin:
- Tripp Lite
- SMX1000RT2U
- New
- 33.95lbs
- 24 X 9 X 20
- Dec 02, 2024
- May 09, 2020
- United States
Request For Quote.