Received! Our sales team will contact you soon.

Tripp SU2200XLCD , Ups, Smartonline 2200va, 1800w, Tower, 100110120127v, L5-20r, 5-1520r, Epo

Make an offer
7 Available

Special Price $1190.75 Regular Price $1607.51

Condition: New
Tripp Lite
TRIPP LITE
Free Shipping for this Item


The Tripp Lite SmartOnline SU2200XLCD Tower UPS provides a reliable battery backup, while managing power and energy usage. Minimize downtime and protect your important data with this tower-style UPS. This Tripp Lite UPS is durable.

<b>OUTPUT</b> <br><b>Output Volt Amp Capacity (VA) </b> <br>2200<br><b>Output kVA capacity (kVA) </b> <br>2.2<br><b>Output Watt Capacity (watts) </b> <br>1800<br><b>Output kW capacity</b> <br>1.8<br><b>Output power factor</b> <br>0.82<br><b>Output Capacity Details</b> <br>ON LINE MODE: Maximum output capacity ratings are reduced for some nominal voltage settings (127/120V 1800 watts, 115V 1620 watts, 110V 1530 watts, 100V 1440 watts). FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1260 watts, 115V 1134 watts, 110V 1071 watts, 100V 1008 watts). <br><b>Crest Factor</b> <br>3:1<br><b>Nominal Output Voltage(s) Supported</b> <br>100V 110V 120V 127V<br><b>Nominal Voltage details</b> <br>120V default<br><b>Frequency compatibility</b> <br>50 / 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversion<br><b>Frequency compatibility details</b> <br>ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup Output matches input frequency when +/-5Hz of nominal Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal. <br><b>Output voltage regulation (line mode) </b> <br>+/- 2%<br><b>Output voltage regulation (Economy line mode) </b> <br>+/- 10%<br><b>Output voltage regulation (Battery mode) </b> <br>+/- 3%<br><b>Built-in UPS output receptacles</b> <br>6 5-15/20R outlet(s) 1 L5-20R outlet(s) <br><b>Built-in controllable switched load banks</b> <br>Two switchable three-outlet load banks<br><b>Output AC waveform (AC mode) </b> <br>Pure Sine wave<br><b>Output AC waveform</b> <br>Pure Sine wave <b>INPUT</b> <br><b>Rated input current (at maximum load) </b> <br>16A<br><b>Nominal Input Voltage(s) Supported</b> <br>100V AC 110V AC 120V AC 127V AC<br><b>Nominal input voltage description</b> <br>120V factory default<br><b>UPS input connection type</b> <br>5-20P<br><b>Input circuit breaker</b> <br>30A<br><b>UPS Input cord length (ft.) </b> <br>10<br><b>UPS Input cord length (m) </b> <br>3<br><b>Recommended Electrical Service</b> <br>15A 120V<br> <b>BATTERY</b> <br><b>Full load runtime (minutes) </b> <br>4.5 min. (1800w) <br><b>Half load runtime (minutes) </b> <br>13 min. (900w) <br><b>Expandable battery runtime</b> <br>Extended runtime supported via optional external battery packs<br><b>External battery pack compatibility</b> <br>BP48V24-2U (limit 1) BP48V60RT-3U (multi-pack compatible) <br><b>Expandable runtime description</b> <br>External battery configurations require the use of Tripp Lites <br>External Battery Configuration Software, see manual for details<br><b>DC system voltage (VDC) </b> <br>48<br<b>Battery recharge rate (included batteries) </b> <br>Less than 3 hours from 10% to 90%<br><b>Replacement battery cartridge (internal UPS battery replacement) </b> <br>RBC48-SUTWR<br><b>Battery Access</b> <br>Battery access door<br><b>Battery replacement description</b> <br>Hot-swappable, user replaceable batteries<br> <b>SURGE / NOISE SUPPRESSION</b> <br><b>UPS AC suppression joule rating</b> <br>570<br><b>UPS AC suppression response time</b> <br>Instantaneous<br><b>UPS Dataline suppression</b> <br>1 line TEL/DSL (1 in / 1 out) 10/100Base T Ethernet<br><b>EMI / RFI AC noise suppression</b> <br>Yes<br> <b>PHYSICAL</b> <br><b>Installation form factors supported with included accessories</b> <br>Tower<br><b>Primary form factor</b> <br>Tower<br><b>UPS housing material</b> <br>Steel<br><b>Cooling method</b> <br>Fan<br> <b>COMMUNICATIONS</b> <br><b>Communications interface</b> <br>USB (HID enabled) DB9 Serial Contact closure EPO (emergency power off) Slot for SNMP/Web interface<br><b>Network monitoring port description</b> <br>Supports detailed monitoring of UPS and site power conditions DB9 port supports RS232 and contact closure communications<br><b>PowerAlert software</b> <br>Included<br><b>Communications cable</b> <br>USB and DB9 cabling included<br><b>WatchDog compatibility</b> <br>Supports Watchdog application, OS and hard-reboot restart options for remote applications<br> <b>LINE / BATTERY TRANSFER</b> <br><b>Transfer time</b> <br>Zero transfer time (0 ms.) in online, double-conversion and frequency regulation / conversion modes <br><b>Low voltage transfer to battery power (setpoint) </b> <br>55V (33% load), 70V (70% load), 100V (100% load) <br><b>High voltage transfer to battery power (setpoint) </b> <br>150<br> <b>CERTIFICATIONS</b> <br><b>UPS Certifications</b> <br>Tested to UL1778 (USA) Tested to CSA (Canada) Tested to NOM (Mexico) Meets FCC Part 15 Category A (EMI) <b> Weight </b> <br> 58.20 <br><b> Item Dimension </b> <br> 15.2 x 13 x 24<br><b> Warranty Information</b><br> 2-year limited warranty
  • Manufacturer:
  • Model Number:
  • Condition:
  • Weight:
  • Dimensions:
  • Updated:
  • Added:
  • Country of Origin:
  • Tripp Lite
  • SU2200XLCD
  • New
  • 60.00lbs
  • 23 X 13 X 15
  • Dec 21, 2024
  • May 06, 2022
  • CN

Request For Quote.


Tripp SU2200XLCD , Ups, Smartonline 2200va, 1800w, Tower, 100110120127v, L5-20r, 5-1520r, Epo

Write a Review