Cart Empty
Tripp PDU3XVSRHWB Tripp-lite Pdu 28.8kw 3-phase Switch Pdu Hardwire 415400380v Input 0u Vertical Taa Retail
Make an offer
Tripp PDU3XVSRHWB Tripp-lite Pdu 28.8kw 3-phase Switch Pdu Hardwire 4
PDU Type
Switched Output Capacity Details
28.8kW (415/240V), 27.7kW (400/230V), 26.3kW (380/220V) total capacity, 40A max per output phase (L1, L2, L3), 20A max per breakered outlet bank, 16A max per C19 outlet, 12A max (10A CE) per C13 outlet Frequency Compatibility
50 / 60 Hz Output Receptacles
(24) C13, (6) C19 Output Nominal Voltage
220 (380V input), 230 (400V input) 240 (415V input) Overload Protection
6 20A circuit breakers, 1 per outlet bank PDU Input Voltage
380, 400, 415 Recommended Electrical Service
External circuit breaker - 3 pole, 415V rated minimum, 50A, Wiring - 5C, 8AWG (10mm2), 75C rated minimum Conduit - 3/4 in. (19mm) minimum, flexible Maximum Input Amps
40 PDU Plug Type
Hardwire Input Phase
3-Phase Reported Load Segments
Reports input current per phase (L1, L2, L3), plus output current for each output load bank (B1-B6) and individual output receptacle (1-30), Outlets are color-coded and labelled for phase and load bank identification L1-N feeds black outlets (B1, B4), L2-N feeds dark-gray outlets (B2, B5), L3-N feeds light-gray outlets (B3, B6) Front Panel LCD Display
Large digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature and Humidity information (requires ENIVIROSENSE option) Small digital display provides detail on the measurement the large display is reporting: Input-phase (L), Load bank (B), Sensor (S), Outlet (), Load unbalance % (UB), Output power (OP) Front Panel LEDs
Set of 6 LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage (%UB), Temperature (T), Humidity (%RH) One additional LED for each output receptacle offers power availability information: GREEN (Power ON, load bank capacity <80%), YELLOW (Power ON, load bank capacity >80%), RED (Power OFF/undervoltage), RED FLASHING (Power OFF/breaker trip) Switches
Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options Additional MODE button advances the LEDs to view the next measurement Material of Construction
Metal Form Factors Supported
Vertical rackmount installation supported with included mounting brackets supports toolless mounting in button-mount compatible racks PDU Form Factor
0U, Vertical Operating Temperature Range
32 to 122oF (0-50oC) Storage Temperature Range
5 to 140oF (-15 to 60oC)
Switched Output Capacity Details
28.8kW (415/240V), 27.7kW (400/230V), 26.3kW (380/220V) total capacity, 40A max per output phase (L1, L2, L3), 20A max per breakered outlet bank, 16A max per C19 outlet, 12A max (10A CE) per C13 outlet Frequency Compatibility
50 / 60 Hz Output Receptacles
(24) C13, (6) C19 Output Nominal Voltage
220 (380V input), 230 (400V input) 240 (415V input) Overload Protection
6 20A circuit breakers, 1 per outlet bank PDU Input Voltage
380, 400, 415 Recommended Electrical Service
External circuit breaker - 3 pole, 415V rated minimum, 50A, Wiring - 5C, 8AWG (10mm2), 75C rated minimum Conduit - 3/4 in. (19mm) minimum, flexible Maximum Input Amps
40 PDU Plug Type
Hardwire Input Phase
3-Phase Reported Load Segments
Reports input current per phase (L1, L2, L3), plus output current for each output load bank (B1-B6) and individual output receptacle (1-30), Outlets are color-coded and labelled for phase and load bank identification L1-N feeds black outlets (B1, B4), L2-N feeds dark-gray outlets (B2, B5), L3-N feeds light-gray outlets (B3, B6) Front Panel LCD Display
Large digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature and Humidity information (requires ENIVIROSENSE option) Small digital display provides detail on the measurement the large display is reporting: Input-phase (L), Load bank (B), Sensor (S), Outlet (), Load unbalance % (UB), Output power (OP) Front Panel LEDs
Set of 6 LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage (%UB), Temperature (T), Humidity (%RH) One additional LED for each output receptacle offers power availability information: GREEN (Power ON, load bank capacity <80%), YELLOW (Power ON, load bank capacity >80%), RED (Power OFF/undervoltage), RED FLASHING (Power OFF/breaker trip) Switches
Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options Additional MODE button advances the LEDs to view the next measurement Material of Construction
Metal Form Factors Supported
Vertical rackmount installation supported with included mounting brackets supports toolless mounting in button-mount compatible racks PDU Form Factor
0U, Vertical Operating Temperature Range
32 to 122oF (0-50oC) Storage Temperature Range
5 to 140oF (-15 to 60oC)
- Manufacturer:
- Model Number:
- Condition:
- Weight:
- Dimensions:
- Updated:
- Added:
- Tripp Lite
- PDU3XVSRHWB
- New
- 17.13lbs
- 6 X 77 X 7
- Jun 28, 2024
- Mar 04, 2020
Request For Quote.
Tripp PDU3XVSRHWB Tripp-lite Pdu 28.8kw 3-phase Switch Pdu Hardwire 415400380v Input 0u Vertical Taa Retail