Tripp PDUMNV30HV2LX Tripp-lite Pdu 0u 5.8kw Single-phase Monitored Pdu 208 240v
Make an offer
General InformationThe PDUMNV30HV2LX 5.8kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime. The 0U PDU features 42 outlets (36 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. A digital ammeter allows you to monitor each load bank's current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.Technical InformationPDU Type: MonitoredPhase: Single PhaseInput Receptacles: NEMA L6-30POutput Receptacles: 6 x IEC 60320 C19Output Receptacles: 36 x IEC 60320 C13Power DescriptionInput Voltage: 230 V ACOutput Voltage: 200 V ACOutput Voltage: 208 V ACOutput Voltage: 240 V ACPower Rating (Watt): 5800 WInput Current: 30 AManagementManagement: Protocols: IPv4 IPv6 HTTP HTTPS SMTP SNMPv1 SNMPv2 SNMPv3 telnet SSH FTP DHCP NTP Physical CharacteristicsMounting Orientation: VerticalPlacement: RackForm Factor: Rack-mountableRack Height: 0UHeight: 70"Width: 2.2"Depth: 2.7"Weight (Approximate): 15 lbMiscellaneousPackage Contents: PDUMNV30HV2LX 42-Outlet PDU Built-in LX Platform Interface Configuration Cable 42 x Plug-lock Insert Sleeves Rack-mounting Hardware Mounting Bracket Accessory Owner's Manual Environmentally Friendly: YesEnvironmental Certification: RoHSCountry of Origin: TaiwanTAA Compliant: YesWarrantyLimited Warranty: 2 Year
OVERVIEW
PDU Type
Monitored
OUTPUT
Output Capacity Details
5.8kW (240V), 5kW (208V), 4.8kW (200V) total capacity / 30A max (Agency de-rated to 24A), 20A max per breakered outlet bank,16A max per C19 outlet, 12A max per C13 outlet
Frequency Compatibility
50 / 60 Hz
Output Receptacles
(36) C13
(6) C19
Output Nominal Voltage
200
208
240
Overload Protection
Two 20A breakers protect 21 outlets each
Customized Load Management Receptacles
n/a
INPUT
PDU Input Voltage
200
208
240
Recommended Electrical Service
30A 208/240V
Maximum Input Amps
30
Maximum Input Amps Details
Agency de-rated to 24A continuous
PDU Plug Type
NEMA L6-30P
Input Cord Length (m)
3.05
Input Phase
Single-Phase
USER INTERFACE, ALERTS and CONTROLS
Front Panel LCD Display
Digital meter reports PDU output current in amps, Scroll IP-address information, Display can be rotated 180 degrees for installation with the input cable at the top
Front Panel LEDs
Front panel LEDs indicate which loading segment the digital LCD current display is reporting Bank 1 LED indicates the meter is reporting load level for outlets 1-21, Bank 2 LED indicates the meter is reporting load level for outlets 22-42, Both LEDs lighted indicates the meter is reporting load level for all outlets combined
Switches
Press the SCROLL IP button and release to display the configured IP address in 2 digit intervals,Press the SELECT / ROTATE button and release after one second to advance the local display power power consumption for the 3 reported segments: Bank 1, Bank 2 and Banks 1+2, Press the SELECT / ROTATE button and release after two seconds to rotate the display 180 degrees
Current Measurement Accuracy (Amps)
+/-2%
PHYSICAL
Form Factors Supported
0U vertical rackmount installation supported with included mounting brackets, supports toolless mounting in button-mount compatible racks
PDU Form Factor
Vertical (0U)
ENVIRONMENTAL
Storage Temperature Range
5 to 140F (-15 to 60C)
Relative Humidity
5-95% non-condensing
Operating Elevation (ft.)
0-10,000
Operating Elevation (m)
0-3000
COMMUNICATIONS
SNMP Compatibility
Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and SNMP management systems
CERTIFICATIONS
Certifications
Tested to UL60950-1: 2007 (USA), CAN/CSA-C22.2 NO. 60950-1-07 (Canada), FCC Class A Part 15 (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
Item Dimension (L"xW"xH")
5 x 6 x 73
Weight
16.50 LB
Warranty Information
2 Years Warranty
PDU Type
Monitored
OUTPUT
Output Capacity Details
5.8kW (240V), 5kW (208V), 4.8kW (200V) total capacity / 30A max (Agency de-rated to 24A), 20A max per breakered outlet bank,16A max per C19 outlet, 12A max per C13 outlet
Frequency Compatibility
50 / 60 Hz
Output Receptacles
(36) C13
(6) C19
Output Nominal Voltage
200
208
240
Overload Protection
Two 20A breakers protect 21 outlets each
Customized Load Management Receptacles
n/a
INPUT
PDU Input Voltage
200
208
240
Recommended Electrical Service
30A 208/240V
Maximum Input Amps
30
Maximum Input Amps Details
Agency de-rated to 24A continuous
PDU Plug Type
NEMA L6-30P
Input Cord Length (m)
3.05
Input Phase
Single-Phase
USER INTERFACE, ALERTS and CONTROLS
Front Panel LCD Display
Digital meter reports PDU output current in amps, Scroll IP-address information, Display can be rotated 180 degrees for installation with the input cable at the top
Front Panel LEDs
Front panel LEDs indicate which loading segment the digital LCD current display is reporting Bank 1 LED indicates the meter is reporting load level for outlets 1-21, Bank 2 LED indicates the meter is reporting load level for outlets 22-42, Both LEDs lighted indicates the meter is reporting load level for all outlets combined
Switches
Press the SCROLL IP button and release to display the configured IP address in 2 digit intervals,Press the SELECT / ROTATE button and release after one second to advance the local display power power consumption for the 3 reported segments: Bank 1, Bank 2 and Banks 1+2, Press the SELECT / ROTATE button and release after two seconds to rotate the display 180 degrees
Current Measurement Accuracy (Amps)
+/-2%
PHYSICAL
Form Factors Supported
0U vertical rackmount installation supported with included mounting brackets, supports toolless mounting in button-mount compatible racks
PDU Form Factor
Vertical (0U)
ENVIRONMENTAL
Storage Temperature Range
5 to 140F (-15 to 60C)
Relative Humidity
5-95% non-condensing
Operating Elevation (ft.)
0-10,000
Operating Elevation (m)
0-3000
COMMUNICATIONS
SNMP Compatibility
Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and SNMP management systems
CERTIFICATIONS
Certifications
Tested to UL60950-1: 2007 (USA), CAN/CSA-C22.2 NO. 60950-1-07 (Canada), FCC Class A Part 15 (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
Item Dimension (L"xW"xH")
5 x 6 x 73
Weight
16.50 LB
Warranty Information
2 Years Warranty
- Manufacturer:
- Model Number:
- Condition:
- Weight:
- Dimensions:
- Updated:
- Added:
- Country of Origin:
- Tripp Lite
- PDUMNV30HV2LX
- New
- 16.50lbs
- 73 X 6 X 6
- Dec 21, 2024
- Nov 02, 2022
- CN
Request For Quote.
Tripp PDUMNV30HV2LX Tripp-lite Pdu 0u 5.8kw Single-phase Monitored Pdu 208 240v