Tripp SMART3000RM2U Ups Smart 3000va 2250w Rackmount Avr 120v Usb Db9 Snmp 2urm - 3000 Va-2250 W - 120 V Ac - 3.50 Minute Stand-by Time - 2u - 8 X Nema 5-15-20r, 1 X Nema L5-30r - Over Voltage, Under Voltage
Make an offerProvides complete battery backup and pure sine wave power output for servers, switches and other high-end distributed IT equipment.
- UPC Code: 037332096685
- UPS Type: Line-Interactive
- Input Phase: Single-Phase
- Rated input current (Maximum Load): 24.0A
- Nominal Input Voltage(s) Supported: 120V AC
- UPS Input Connection Type: L5-30P
- UPS Input Cord Length (ft.): 10
- Recommended Electrical Service: 30A 120V
- Output Capacity (VA): 3000
- Output Capacity (kVA): 3
- Output Capacity (Watts): 3000
- Output Capacity (kW): 3
- Power Factor: 1
- Nominal Voltage Details: 120v nominal output in battery mode
- Frequency Compatibility: 50 / 60 Hz
- Output Voltage Regulation (Battery Mode): 120V (-10%, +6%)
- Load Management Receptacles: Two switched single outlet load banks (2x 5-20R and 2x 5-20R )
- Output AC Waveform (AC Mode): Pure Sine wave
- Output AC Waveform (Battery Mode): Pure Sine wave
- Nominal Output Voltage(s) Supported: 100V; 110V; 120V; 125V
- Output Receptacles: (6) 5-20R; (1) L5-30R
- Individually Controllable Load Banks: Yes
- Battery Type: Valve Regulated Lead Acid (VRLA)
- Runtime Full Load (min.): 3 min. (3000W)
- Runtime Half Load (min.): 9 min. (1500W)
- DC System Voltage (VDC): 72
- Battery Recharge Rate (Included Batteries): Less than 5 hours from 10% to 90% (typical, full load discharge)
- Battery Access: Front panel battery access door
- Internal UPS Replacement Battery Cartridge: 744-A3122
- Battery Replacement Description: Hot-swappable, user replaceable batteries
- Voltage Regulation Description: Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 80 to 151
- Front Panel LCD Display: Front panel rotatable LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
- Switches: 5 pushbutton switches control OFF / ON power status, ENTER, UP, and DOWN selection and ESC control functions
- Alarm Cancel Operation: Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and perform the applicable action to resolve the condition. If the alarm status changes, the alarm beeps again, overriding the previous alarm silencing
- Audible Alarm: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
- UPS AC Suppression Response Time: Instantaneous
- EMI / RFI AC Noise Suppression: Yes
- Primary Form Factor: Rackmount; Tower
- Rack Height: 2U
- Cooling Method: Fan
- Included Mounting Accessory Description: Included mounting bracket enables installation in 4 post racks. Two ABS mounting stands enables the UPS to be configured in an upright tower orientation.
- Installation Form Factors Supported with Included Accessories: 4 post 19 inch rackmount; Tower
- Minimum Required Rack Depth (inches): 27
- Primary UPS Depth (mm): 602
- Primary UPS Height (mm): 86
- Primary UPS Width (mm): 437
- Shipping Dimensions (hwd / in.): 9.44 x 22.83 x 30.86
- Shipping Weight (lbs.): 87.74
- UPS Housing Material: Steel
- UPS Power Module Dimensions (hwd, in.): 3.4 x 17.2 x 23.7
- Unit Dimensions (hwd / in.): 3.400 x 17.2 x 23.7
- Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity: 20 to 95%, non-condensing
- AC Mode Efficiency Rating (100% Load): 96%
- Network Management Cards: WEBCARDLXE
- Network Monitoring Port Description: Network Card Optional
- PowerAlert Software: For local monitoring via the UPSrs built-in communication ports, download PowerAlert Local software at https://tripplite.eaton.com/poweralert
- Communications Cable: USB and DB9 cabling included
- Network Management Card Description: One slot for optional WEBCARDLXE web card. Note: Not compatible with WEBCARDLX
- Communications Interface: Contact closure; DB9 Serial; Slot for SNMP/Web interface; USB (HID enabled)
- Transfer Time: 1-4ms for normal mode
- Low Voltage Transfer to Battery Power (Setpoint): 80
- High Voltage Transfer to Battery Power (Setpoint): 151
- Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
- High Availability UPS Features: Automatic Voltage Regulation (AVR); Expandable battery backup; Hot swappable batteries; Remote management; Sine wave output; Surge/noise protection
- Green Energy-Saving Features: Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
- UPS Applications: Large Network
- Product Certifications: CSA (Canada); UL 1778
- Product Compliance: CE (Europe); ENERGY STAR Qualified; FCC Part 15 Class B (USA)
- Product Warranty Period (Worldwide): 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.
- Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance
Power protection and battery backup for servers and network hardware.Pure sine wave output improves compatibility with sensitive equipment.Advanced AVR corrects power sags and overvoltages.LCD shows power conditions and permits easy access to settings.Network card slot supports optional remote access and network management.USB and serial ports connect to computers for power management.Model Number: SMART3000RM2U
- Manufacturer:
- Model Number:
- Condition:
- Weight:
- Dimensions:
- Updated:
- Added:
- Country of Origin:
- Tripp Lite
- SMART3000RM2U
- New
- 82.00lbs
- 31 X 10 X 25
- Dec 21, 2024
- Sep 11, 2022
- CN
Request For Quote.
Tripp SMART3000RM2U Ups Smart 3000va 2250w Rackmount Avr 120v Usb Db9 Snmp 2urm - 3000 Va-2250 W - 120 V Ac - 3.50 Minute Stand-by Time - 2u - 8 X Nema 5-15-20r, 1 X Nema L5-30r - Over Voltage, Under Voltage