Tripp PDU3VN6L2130B Tripp-lite 3-phase Monitored Pdu 10kw 42 240v Outlets Retail
Make an offer
Tripp PDU3VN6L2130B Tripp-lite 3-phase Monitored Pdu 10kw 42 240v Out
Output
Output Capacity Details : 10kW (240V), 9.6kW (230V), 9.1kW (220V), 8.6kW (208V), 8.3kW (200V) total capacity 13.9A max per breakered outlet bank 12A max per C13 outlet
Frequency Compatibility : 50 / 60 Hz
utput Receptacles : (42) C13 (6) C19
Output Nominal Voltage : 200 208 240
Overload Protection : 3 20A circuit breakers, one per output load bank Input
PDU Input Voltage : 200 208 240
Recommended Electrical Service : 30A 208/240V with L21-30R outlet
Maximum Input Amps : 24
PDU Plug Type : NEMA L21-30P
Input Cord Length (m) : 1.8
Input Phase : 3-Phase Reported Load Segments
Reports input current per phase (L1, L2, L3) and output current for each breakered load bank (13.9A balanced max per banks B1-B3) Outlets are color-coded and labelled for phase and load bank identification L1-L2 feeds black outlets (B1) L2-L3 feeds dark-gray outlets (B2) L3-L1 feeds light-gray outlets (B3) Front Panel LCD Display
Large digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature and Humidity information (requires ENIVIROSENSE option) Small digital display provides detail on the measurement the large display is reporting: Input-phase (L), Load bank (B), Sensor (S), Load unbalance (UB), Output power (OP) Front Panel LEDs
Set of 6 LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage (percent UB), Temperature (T), Humidity (percent RH) One additional LED for each output load bank (B1-B3) offers information power availablity: GREEN (<80 percent load), YELLOW (>80% load), RED (Power OFF), RED FLASHING (Power OFF/breaker trip) Switches
Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options Additional MODE button advances the LEDs to view the next measurement Material of Construction
Metal Form Factors Supported
Vertical rackmount installation supported with included mounting brackets supports tooless mounting in button-mount compatible racks PDU Form Factor
Vertical (0U) Operating Temperature Range
32 to 122F (0C to 50C) Storage Temperature Range
5 to 140F (-15C to 60C) Relative Humidity
5-95 percent non-condensing Operating Elevation (m)
0 - 3000 m Certifications
Tested to UL60950-1 (USA) CAN60950-1 (Canada), NOM (Mexico), Class A (Emissions), ROHS, TAA Compliant Item Dimension (L inchxW inchxH inch)
7 x 10 x 76
Weight
33.00 lb
Warranty Information
2-year limited warranty
Output Capacity Details : 10kW (240V), 9.6kW (230V), 9.1kW (220V), 8.6kW (208V), 8.3kW (200V) total capacity 13.9A max per breakered outlet bank 12A max per C13 outlet
Frequency Compatibility : 50 / 60 Hz
utput Receptacles : (42) C13 (6) C19
Output Nominal Voltage : 200 208 240
Overload Protection : 3 20A circuit breakers, one per output load bank Input
PDU Input Voltage : 200 208 240
Recommended Electrical Service : 30A 208/240V with L21-30R outlet
Maximum Input Amps : 24
PDU Plug Type : NEMA L21-30P
Input Cord Length (m) : 1.8
Input Phase : 3-Phase Reported Load Segments
Reports input current per phase (L1, L2, L3) and output current for each breakered load bank (13.9A balanced max per banks B1-B3) Outlets are color-coded and labelled for phase and load bank identification L1-L2 feeds black outlets (B1) L2-L3 feeds dark-gray outlets (B2) L3-L1 feeds light-gray outlets (B3) Front Panel LCD Display
Large digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature and Humidity information (requires ENIVIROSENSE option) Small digital display provides detail on the measurement the large display is reporting: Input-phase (L), Load bank (B), Sensor (S), Load unbalance (UB), Output power (OP) Front Panel LEDs
Set of 6 LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage (percent UB), Temperature (T), Humidity (percent RH) One additional LED for each output load bank (B1-B3) offers information power availablity: GREEN (<80 percent load), YELLOW (>80% load), RED (Power OFF), RED FLASHING (Power OFF/breaker trip) Switches
Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options Additional MODE button advances the LEDs to view the next measurement Material of Construction
Metal Form Factors Supported
Vertical rackmount installation supported with included mounting brackets supports tooless mounting in button-mount compatible racks PDU Form Factor
Vertical (0U) Operating Temperature Range
32 to 122F (0C to 50C) Storage Temperature Range
5 to 140F (-15C to 60C) Relative Humidity
5-95 percent non-condensing Operating Elevation (m)
0 - 3000 m Certifications
Tested to UL60950-1 (USA) CAN60950-1 (Canada), NOM (Mexico), Class A (Emissions), ROHS, TAA Compliant Item Dimension (L inchxW inchxH inch)
7 x 10 x 76
Weight
33.00 lb
Warranty Information
2-year limited warranty
- Manufacturer:
- Model Number:
- Condition:
- Weight:
- Dimensions:
- Updated:
- Added:
- Tripp Lite
- PDU3VN6L2130B
- New
- 22.76lbs
- 7 X 76 X 10
- Jun 28, 2024
- Jul 25, 2020
Request For Quote.
Tripp PDU3VN6L2130B Tripp-lite 3-phase Monitored Pdu 10kw 42 240v Outlets Retail