Tripp PDU3XEVSRHWB 28.8kw 3-phase Switched Pdu, Lx Platform Interface, 220230240v Outlets (24 C13
Make an offer
/6 C19), LCD, HARDWIRE 380/400/415V INPUT, 0U, TAA
OVERVIEW
PDU Type
Switched
OUTPUT
Frequency Compatibility
50 / 60 Hz
Output Capacity Details
28.8kW (415/240V), 27.7kW (400/230V), 26.3kW (380/220V) total capacity, 40A max per output phase (L1, L2, L3), 20A max per breakered outlet bank, 16A max per C19 outlet, 12A max per C13 outlet
Output Receptacles
(24) C13, (6) C19
Output Nominal Voltage
220 (380V input), 230 (400V input), 240 (415V input)
Overload Protection
6 20A breakers protect 4 C13 and 1 C19 outlet each
INPUT
PDU Input Voltage
380, 400
Recommended Electrical Service
External circuit breaker - 3 pole, 415V rated, 50A, Wiring - 5C, pound 8AWG (10mm2), 75C rated minimum, Conduit - 3/4 in. (19mm) minimum, flexible
Maximum Input Amps
40
PDU Plug Type
Hardwire
Input Phase
3-Phase
USER INTERFACE, ALERTS and CONTROLS
Reported Load Segments
Reports input current per phase (L1, L2, L3), plus output current for each output load bank (B1-B6) and individual output receptacle (1-30), Outlets are color-coded and labeled for phase and load bank identification, L1-N feeds black outlets (B1, B4), L2-N feeds dark-gray outlets (B2, B5), L3-N feeds light-gray outlets (B3, B6)
Front Panel LCD Display
Touchscreen LCD reports NETWORK DATA (IP address, Subnet Mask, Gateway, MAC Address, Device Name, Model, Serial Number), INPUT PHASE DATA (Amperage, Wattage, Voltage per phase, plus Unbalance percentage), LOAD BANK DATA (Amperage, Wattage, Voltage per load bank, plus total PDU output in watts), OUTLET DATA (Amperage, Wattage per outlet), CONFIGURATION DATA (Listing of current configuration settings), ENVIRONMENTAL DATA (Reports data and status of E2 sensor modules, Sensor options are available for temperature and humidity, plus input and output dry contacts), MOBILE ACCESS (Generates a unique QR code to view reported PDU details on a mobile device)
Front Panel LEDs
One LED for each output receptacle offers power availability information: GREEN (Power ON, load bank capacity <80%), YELLOW (Power ON, load bank capacity >80%), RED (Power OFF/undervoltage), RED FLASHING (Power OFF/breaker trip), LED OFF (Power OFF). Network Activity (Green): Flashes for network activity. Link/Network Speed (Yellow): On steady for any speed.
Switches
LX Platform Interface: Recessed reset switch for interface reboot and factory reset
Current Measurement Accuracy (Amps)
+/-1%
Voltage Measurement Accuracy (Volts)
+/-1%
Power Measurement Accuracy (Watts)
+/-1%
PHYSICAL
Form Factors Supported
Vertical rackmount installation supported with included mounting brackets, supports toolless mounting in button-mount compatible racks
Material of Construction
Metal
PDU Form Factor
Vertical (0U)
ENVIRONMENTAL
Operating Temperature Range
32 to 122F (0C to 50C)
Storage Temperature Range
-30oC to +60oC (-22oF to +140oF)
Relative Humidity
5% to 95% non-condensing
COMMUNICATIONS
PowerAlert Software
LX Platform Interface: PowerAlert Device Manager15 (PADM15)
Communications Cable
USB B-to-USB A Configuration/Console Access cable
Network Monitoring Port
RJ45 Network port, RJ45 Config/Console Access port, 2x USB A ports supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules. USB B port (Configuration and Console Access)
SNMP Compatibility
SNMP V1, V2c, V3
Network Speed
10/100 Mbps, 1Gbps
Communications Interface
Pre-installed network card, RS-232, USB
CERTIFICATIONS
Certifications
Tested to UL60950-1: 2007 R12.11, IEC 60950-1: 2005+A1:2009 (USA), CAN/CSA-C22.2 NO. 60950-1-07+A1: 2011 (Canada), NOM (Mexico), Tested to CE (EN 60950-1), FCC/CE Class A (Emissions), RoHS compliant, TAA Compliant
Item Dimension (L"x W"x H")
76 x 7 x 6
Weight
23.00 LB
Warranty Information
2-year limited warranty
PDU Type
Switched
OUTPUT
Frequency Compatibility
50 / 60 Hz
Output Capacity Details
28.8kW (415/240V), 27.7kW (400/230V), 26.3kW (380/220V) total capacity, 40A max per output phase (L1, L2, L3), 20A max per breakered outlet bank, 16A max per C19 outlet, 12A max per C13 outlet
Output Receptacles
(24) C13, (6) C19
Output Nominal Voltage
220 (380V input), 230 (400V input), 240 (415V input)
Overload Protection
6 20A breakers protect 4 C13 and 1 C19 outlet each
INPUT
PDU Input Voltage
380, 400
Recommended Electrical Service
External circuit breaker - 3 pole, 415V rated, 50A, Wiring - 5C, pound 8AWG (10mm2), 75C rated minimum, Conduit - 3/4 in. (19mm) minimum, flexible
Maximum Input Amps
40
PDU Plug Type
Hardwire
Input Phase
3-Phase
USER INTERFACE, ALERTS and CONTROLS
Reported Load Segments
Reports input current per phase (L1, L2, L3), plus output current for each output load bank (B1-B6) and individual output receptacle (1-30), Outlets are color-coded and labeled for phase and load bank identification, L1-N feeds black outlets (B1, B4), L2-N feeds dark-gray outlets (B2, B5), L3-N feeds light-gray outlets (B3, B6)
Front Panel LCD Display
Touchscreen LCD reports NETWORK DATA (IP address, Subnet Mask, Gateway, MAC Address, Device Name, Model, Serial Number), INPUT PHASE DATA (Amperage, Wattage, Voltage per phase, plus Unbalance percentage), LOAD BANK DATA (Amperage, Wattage, Voltage per load bank, plus total PDU output in watts), OUTLET DATA (Amperage, Wattage per outlet), CONFIGURATION DATA (Listing of current configuration settings), ENVIRONMENTAL DATA (Reports data and status of E2 sensor modules, Sensor options are available for temperature and humidity, plus input and output dry contacts), MOBILE ACCESS (Generates a unique QR code to view reported PDU details on a mobile device)
Front Panel LEDs
One LED for each output receptacle offers power availability information: GREEN (Power ON, load bank capacity <80%), YELLOW (Power ON, load bank capacity >80%), RED (Power OFF/undervoltage), RED FLASHING (Power OFF/breaker trip), LED OFF (Power OFF). Network Activity (Green): Flashes for network activity. Link/Network Speed (Yellow): On steady for any speed.
Switches
LX Platform Interface: Recessed reset switch for interface reboot and factory reset
Current Measurement Accuracy (Amps)
+/-1%
Voltage Measurement Accuracy (Volts)
+/-1%
Power Measurement Accuracy (Watts)
+/-1%
PHYSICAL
Form Factors Supported
Vertical rackmount installation supported with included mounting brackets, supports toolless mounting in button-mount compatible racks
Material of Construction
Metal
PDU Form Factor
Vertical (0U)
ENVIRONMENTAL
Operating Temperature Range
32 to 122F (0C to 50C)
Storage Temperature Range
-30oC to +60oC (-22oF to +140oF)
Relative Humidity
5% to 95% non-condensing
COMMUNICATIONS
PowerAlert Software
LX Platform Interface: PowerAlert Device Manager15 (PADM15)
Communications Cable
USB B-to-USB A Configuration/Console Access cable
Network Monitoring Port
RJ45 Network port, RJ45 Config/Console Access port, 2x USB A ports supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules. USB B port (Configuration and Console Access)
SNMP Compatibility
SNMP V1, V2c, V3
Network Speed
10/100 Mbps, 1Gbps
Communications Interface
Pre-installed network card, RS-232, USB
CERTIFICATIONS
Certifications
Tested to UL60950-1: 2007 R12.11, IEC 60950-1: 2005+A1:2009 (USA), CAN/CSA-C22.2 NO. 60950-1-07+A1: 2011 (Canada), NOM (Mexico), Tested to CE (EN 60950-1), FCC/CE Class A (Emissions), RoHS compliant, TAA Compliant
Item Dimension (L"x W"x H")
76 x 7 x 6
Weight
23.00 LB
Warranty Information
2-year limited warranty
- Manufacturer:
- Model Number:
- Condition:
- Weight:
- Dimensions:
- Updated:
- Added:
- Tripp Lite
- PDU3XEVSRHWB
- New
- 13.49lbs
- 3 X 70 X 2
- Oct 19, 2024
- Mar 04, 2020
Request For Quote.
Tripp PDU3XEVSRHWB 28.8kw 3-phase Switched Pdu, Lx Platform Interface, 220230240v Outlets (24 C13