Cart Empty
Apc AP8966 Rack Pdu 2g, Switched, Zerou, 17.2kw, 208v, (20) C13, (12)c19
Make an offer
APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
Output
Nominal Output Voltage
208V
Overload Protection
Yes
Maximum Total Current Draw
48
Output Connections
(12) IEC 320 C19 (Battery Backup)
(20) IEC 320 C13 (Battery Backup)
Input
Nominal Input Voltage
208V 3PH
Input frequency
50/60 Hz
Input Connections
IEC 309 60A 3P+PE
Cord Length
6ft (1.83meters)
Number of Power Cords
1
Load Capacity
17300VA
Maximum Input Current
60A
Maximum Line Current
48A
Regulatory Derated Input Current (North America)
48A
Physical
Color
Black
Environmental
Operating Temperature
32 - 113 oF (0 - 45 oC)
Operating Relative Humidity
5 - 95 %
Operating Elevation
0-10000ft (0-3000meters)
Storage Temperature
-25 - 65 oC
Storage Relative Humidity
5 - 95 %
Storage Elevation
0-50000ft (0-15000meters)
Conformance
Approvals
cUL Listed, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, UL Listed, VCCI Class A
Sustainable Offer Status
RoHS
Compliant
REACH
REACH: Contains No SVHCs
PEP
Available in Documentation tab
EOLI
Available in Documentation tab
Battery Directive
Compliant
Item Dimension ( L inchxW inchxH inch)
5 x 85 x 9 Weight
44 lb Warranty Information
2 years repair or replace
Nominal Output Voltage
208V
Overload Protection
Yes
Maximum Total Current Draw
48
Output Connections
(12) IEC 320 C19 (Battery Backup)
(20) IEC 320 C13 (Battery Backup)
Input
Nominal Input Voltage
208V 3PH
Input frequency
50/60 Hz
Input Connections
IEC 309 60A 3P+PE
Cord Length
6ft (1.83meters)
Number of Power Cords
1
Load Capacity
17300VA
Maximum Input Current
60A
Maximum Line Current
48A
Regulatory Derated Input Current (North America)
48A
Physical
Color
Black
Environmental
Operating Temperature
32 - 113 oF (0 - 45 oC)
Operating Relative Humidity
5 - 95 %
Operating Elevation
0-10000ft (0-3000meters)
Storage Temperature
-25 - 65 oC
Storage Relative Humidity
5 - 95 %
Storage Elevation
0-50000ft (0-15000meters)
Conformance
Approvals
cUL Listed, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, UL Listed, VCCI Class A
Sustainable Offer Status
RoHS
Compliant
REACH
REACH: Contains No SVHCs
PEP
Available in Documentation tab
EOLI
Available in Documentation tab
Battery Directive
Compliant
Item Dimension ( L inchxW inchxH inch)
5 x 85 x 9 Weight
44 lb Warranty Information
2 years repair or replace
- Manufacturer:
- Model Number:
- Condition:
- Weight:
- Dimensions:
- Updated:
- Added:
- Apc - Schneider Electric
- AP8966
- New
- 35.00lbs
- 2 X 72 X 2
- Oct 12, 2024
- Sep 03, 2016
Request For Quote.
Apc AP8966 Rack Pdu 2g, Switched, Zerou, 17.2kw, 208v, (20) C13, (12)c19